Our product quality to provide after-sales service. After the purchase by our professional staff to customer unit for installation. Non-artificial cause quality problem, the warranty period a year, motor warranty for half a year.
note
1, before starting the check whether unloaded the safety of the attached plywood
2, check all lock parts is firm
A, check the screen on case whether sieve surface pressure.
B, inspect rubber pad and screen body and a frame connection.
C, check the vibration motor and screen body connection.
3, check the vibration motor
A, check the power supply voltage
B, check the vibration motor control device interlocking.
C, dismantling the motor of the cover, check the relative phase fan-shaped dollop whether consistent, tighten the screw fan-shaped dollop tighten.
D, two motor installation Angle should be consistent.
4, feeding device
A, tightening disc.
B, check the import and export of whether hose connection, and at the same time don't too tightly sealed, otherwise, it will in the screen when the motion and broken.
Daily maintenance
1. Before starting the:
A. check thick nets and fine nets have damaged
B. each group clamps whether lock
2. Startup:
A. note for abnormal noise
B. the power supply is stable
C. vibration have is the same as shape
3. After use: every time after use that is clean
Maintenance regularly
1. Regular inspection size nets and spring for each part of the body is damaged, whether for vibration and produce damage.
2. The motor operates two weeks or so, must add a timely lithium and manufactured (ZL-3). Total 1500 operating hours, check the bearing, if the damage replaced immediately.
Other note:
In the use of ultrasonic vibration system before, please read carefully the attention, operation according to the instructions, so as to avoid the unnecessary damage to equipment.
1. Ultrasonic vibration sieve input voltage power supply work for ac 220 V.
2. To meet the production requirements in the case, vibration amplitude not more than 200 u m.
3. No load that is not 'network when stretched nets, do not open the ultrasonic vibration sieve power supply. Otherwise, easy to cause the power flow and rack and the damage of the transducer.
4. Sieve must take up, or affect the output and vibration effect. Ultrasonic
5. Transducer aviation plug docking screw must tighten and insulating tape wrapped, prevent into the dust. In use pay attention to protect the fittings.
6. In machines on transducer and connecting check before the plug is lock nut, transducer and rack is lock (lock strength for 40 ~ 50 kg). In use process, pay attention to case and transducer HF connecting cable between the protection, HF connecting cables and transducer socket to pay attention to moistureproof, connection plug and socket no water.
7. If the material conductive, please use the ultrasonic HF connecting cables, lengthened the ultrasonic vibration sieve power and screening the isolation, in order to prevent the material into power box of cause a short-circuit.
8. The change, the inner frame (resonance is) of the incomplete glue with a sharp knife to the wind, do not wallpaper with grinding wheel grinding mill Angle, to prevent the damage resonance.
9. Each ultrasonic system includes a ultrasonic vibration sieve, a power of HF connecting cables, a transducer, a rack. Don't and other manufacturers ultrasonic system use each other, so as to avoid unnecessary loss.
10. Suggest using 504 glue stick nets, sieve net glue, the net surface tension as far as possible book want even (necessary can use tension meter surface tension of the network).
(fault phenomena reason may processing methods:)
1
Turn on the power switch, ultrasonic vibration sieve, ultrasonic power no display don't work
1.220 V power have no electricity
2. Power lines to short circuit
3. The power supply pipe burn off insurance
4. The power supply ship type switch fault
1. Check the 220 V power source
2. Check the power cord, such as in the open circuit, change or repair
3. Insurance replacement pipe
4. Replace ship type switch
2
Ultrasonic vibration sieve out power for "drops" or "drop" continuous noise, or net surface no vibration
1. Ultrasonic transducer to power and vibrating screen of connections between short circuit.
2. Water into the damp or connections to plug conductive material is punctured.
3. Transducer fault
4. Loose didn't lock transducer
1. Using a multimeter to check HF connecting cable and plug (a: 1 to 1 for interlinked, two to two interlinked, between two line insulation resistance not less than 1 M Ω. B. transducer and HF connecting cables even, the multimeter on measurement, the measurement transducer capacitance files between two qualification of capacitance value shall be, let > 3 nF, or show that HF connecting cables to at least one line transducer broken).
2. Check the link, such as there is open circuit plug short circuit timely repair check the cable plug insulation resistance less than 1 value, such as M Ω is replaced plug
3. Check whether transducer lock
4. Detection methods such as shown pathogen. Failure could not be ruled out please return factory maintenance.
3
Ultrasonic vibration sieve power supply, the net surface vibration amplitude small amplitude weak.
1. The connecting cable and plug insulating value is not enough.
2. No lock transducer
3. No take up, or screen the glue
4. Transducer and network between the base have stolen goods.
5. Resonance device, or a crack article support by frequency disorder.
1. Check the cable and plug the insulation of the value.
2. Use big wrench screw transducer.
3. The taut, or to stretch tight nets.
4. Clean up between the base of the debris.
5. Check the resonance or to repair service.
Note: ultrasound screening system a year warranty, lifelong maintenance. Ultrasonic vibration sieve, power supply, HF connecting cables, transducer, once changes warranty invalid frame.